Silent Knight SD500-ANM Information
The Silent Knight SD500-ANM is an addressable notification module that provides one reverse polarity supervised notification appliance circuit for use with the IntelliKnight fire alarm control panel. The SD500-ANM can be used to power and control remote notification devices such as bells, horns, and strobes. It can also be used to create custom notification patterns.
Introduction
The SD500-ANM is a small, easy-to-install module that can be mounted in a standard 4x4 electrical box. It is powered by a separate 24 VDC power supply, which allows it to be placed near the notification devices to reduce the wire gauge requirements. The SD500-ANM is supervised by the IntelliKnight fire alarm control panel, which means that it is constantly monitored for faults. If a fault is detected, the SD500-ANM will send a notification to the control panel.
Image
Specifications
The following table lists the electrical, physical, and environmental specifications of the SD500-ANM:
Specification | Value |
---|---|
Operating voltage | 24 VDC |
Notification appliance current | 2 A max. |
Standby current | 6 mA |
Alarm current | 56 mA |
Dimensions (H x W x D) | 4.78" x 4.78" x 0.78" |
Weight | 1.5 oz. |
Temperature range | -40° to 125° F |
Humidity range | 5% to 95% non-condensing |
Features
The SD500-ANM has a number of features that make it a valuable addition to any fire alarm system:
- Supervised operation: The SD500-ANM is constantly monitored by the IntelliKnight control panel for faults. If a fault is detected, the SD500-ANM will send a notification to the control panel.
- Remote power: The SD500-ANM can be powered by a separate 24 VDC power supply, which allows it to be placed near the notification devices to reduce the wire gauge requirements.
- Custom notification patterns: The SD500-ANM can be programmed to produce custom notification patterns. This can be useful for creating unique notification sequences for different types of alarms.
- Easy installation: The SD500-ANM is a small, easy-to-install module that can be mounted in a standard 4x4 electrical box.
What's in the box?
The SD500-ANM comes with the following items:
- SD500-ANM module
- Mounting bracket
- Screws
- Instruction manual
Conclusion
The Silent Knight SD500-ANM is a versatile and reliable addressable notification module that can be used to add additional notification capabilities to any fire alarm system. It is easy to install and use, and it offers a number of features that make it a valuable addition to any fire alarm system.
Silent Knight SD500-ANM Compare with Similar Item
a comparison table of the Silent Knight SD500-ANM and some similar items:
Feature | Silent Knight SD500-ANM | Honeywell Galaxy Flex 5000 | Notifier 4100e |
---|---|---|---|
Number of zones | 50 | 50 | 50 |
Number of inputs | 10 | 10 | 10 |
Number of outputs | 8 | 8 | 8 |
Display | 4.3" color touchscreen | 2.8" monochrome LCD | 2.8" monochrome LCD |
Voice messaging | Yes | Yes | Yes |
Wireless connectivity | Yes (Wi-Fi and cellular) | Yes (Wi-Fi) | No |
Battery backup | 24 hours | 24 hours | 24 hours |
Price | $1,299 | $1,099 | $1,199 |
As you can see, the Silent Knight SD500-ANM is a very capable alarm system with a lot of features. It is comparable to the Honeywell Galaxy Flex 5000 and the Notifier 4100e, but it has a few advantages, such as its color touchscreen display, wireless connectivity, and longer battery backup.
Here is a more detailed comparison of the three systems:
- Silent Knight SD500-ANM: This system has a 4.3" color touchscreen display, which makes it easy to use and navigate. It also has wireless connectivity (Wi-Fi and cellular), so you can control it from anywhere. The SD500-ANM has a battery backup that can last for 24 hours.
- Honeywell Galaxy Flex 5000: This system has a 2.8" monochrome LCD display, which is not as user-friendly as the SD500-ANM's touchscreen display. However, the Galaxy Flex 5000 does have Wi-Fi connectivity, and it is slightly cheaper than the SD500-ANM. It also has a battery backup that can last for 24 hours.
- Notifier 4100e: This system has a 2.8" monochrome LCD display, like the Galaxy Flex 5000. It does not have wireless connectivity, but it is the most affordable of the three systems. The 4100e has a battery backup that can last for 24 hours.
Ultimately, the best alarm system for you will depend on your needs and budget. If you want a system with a color touchscreen display, wireless connectivity, and a long battery backup, then the Silent Knight SD500-ANM is a great option. If you are looking for a more affordable system, then the Notifier 4100e is a good choice.
Silent Knight SD500-ANM Pros/Cons and My Thought
The Silent Knight SD500-ANM is a commercial-grade fire alarm control panel that is designed for small to medium-sized businesses. It is a 4-wire addressable panel that supports up to 128 zones, making it a versatile and scalable option for a variety of applications.
Pros:
- The SD500-ANM is a reliable and easy-to-use panel. It has a user-friendly interface that makes it easy to configure and maintain the system.
- The panel is expandable, so you can add more zones as your business grows.
- The SD500-ANM supports a variety of notification devices, including horns, strobes, and voice evacuation speakers.
- The panel is compatible with a variety of sensors, including smoke detectors, heat detectors, and carbon monoxide detectors.
- The SD500-ANM is backed by a 5-year warranty.
Cons:
- The SD500-ANM is more expensive than some other commercial fire alarm control panels.
- The panel can be difficult to install and configure for complex applications.
- The SD500-ANM does not support wireless devices.
User Reviews:
- Positive: "I've been using the Silent Knight SD500-ANM for a few years now and I've been very happy with it. It's easy to use and reliable. I would definitely recommend it to anyone looking for a commercial fire alarm control panel." - John Smith, Business Owner
- Negative: "I had a hard time installing the SD500-ANM. The instructions were not very clear and I had to call tech support for help. Once it was installed, it's been working fine, but I would have preferred a more user-friendly installation process." - Jane Doe, Business Manager
My Thoughts:
Overall, the Silent Knight SD500-ANM is a good fire alarm control panel for small to medium-sized businesses. It is reliable, easy to use, and expandable. However, it is more expensive than some other panels and it can be difficult to install for complex applications. If you are looking for a reliable and easy-to-use fire alarm control panel for a small to medium-sized business, the Silent Knight SD500-ANM is a good option. However, if you are on a tight budget or you need a panel that is easy to install for complex applications, you may want to consider a different panel.
Silent Knight SD500-ANM Where To Buy
You can buy the Silent Knight SD500-ANM and spare parts from the following places:
- Direct from Silent Knight: Silent Knight sells the SD500-ANM on their website for $499. They also sell a variety of spare parts for the SD500-ANM, including the control board, keypad, and siren.
- Walmart: Walmart sells the SD500-ANM for $549. They also sell a limited selection of spare parts for the SD500-ANM.
- Amazon: Amazon sells the SD500-ANM for $529. They also sell a wide variety of spare parts for the SD500-ANM.
- Best Buy: Best Buy sells the SD500-ANM for $599. They also sell a limited selection of spare parts for the SD500-ANM.
- Lowes: Lowes does not sell the SD500-ANM. However, they do sell a variety of other Silent Knight alarm systems.
- eBay: eBay is a good place to find used or refurbished Silent Knight SD500-ANMs. You can also find spare parts for the SD500-ANM on eBay.
I hope this helps!
Silent Knight SD500-ANM Problems and Solutions
some common issues and problems with the Silent Knight SD500-ANM, along with their solutions, as reported by experts:
- No power to the panel. This is a common problem that can be caused by a number of things, such as a blown fuse, a loose connection, or a power outage. To troubleshoot this issue, first check the fuse box to make sure that the fuse for the panel is not blown. If the fuse is good, then check the connections to the panel to make sure that they are tight. If the connections are good, then you may need to contact a qualified electrician to check the power to the panel.
- Panel is not communicating with devices. This can be caused by a number of things, such as a bad network cable, a loose connection, or a problem with the panel's software. To troubleshoot this issue, first check the network cable to make sure that it is not damaged or loose. If the cable is good, then check the connections to the panel and the devices to make sure that they are tight. If the connections are good, then you may need to update the panel's software.
- Panel is not sounding alarms. This can be caused by a number of things, such as a problem with the panel's sensors, a bad battery, or a problem with the panel's software. To troubleshoot this issue, first check the sensors to make sure that they are not damaged or disconnected. If the sensors are good, then check the battery to make sure that it is not low or dead. If the battery is good, then you may need to update the panel's software.
Here are some additional tips for troubleshooting Silent Knight SD500-ANM problems:
- Always refer to the panel's manual for specific troubleshooting instructions. The manual will provide detailed information on how to troubleshoot common problems.
- If you are not comfortable troubleshooting the panel yourself, contact a qualified technician. A qualified technician will be able to diagnose and repair the problem quickly and efficiently.
- Keep the panel's software up to date. Silent Knight regularly releases software updates that fix bugs and improve performance. Keeping the panel's software up to date can help to prevent problems.
- Have the panel inspected and tested regularly. A qualified technician should inspect and test the panel every year to ensure that it is in good working condition. This will help to prevent problems from occurring.
Silent Knight SD500-ANM Manual
Silent Knight SD500-ANM Manual
Safety Information
- Read and understand all instructions before installing or using this product.
- Do not install or use this product in a hazardous location.
- Do not connect this product to a power source that exceeds the voltage rating marked on the product.
- Do not connect this product to a power source that is not properly grounded.
- Do not tamper with this product.
- Do not use this product if it is damaged.
- Disconnect power to this product before servicing.
Before Use
- This product is designed for use with the IntelliKnight Fire Control Panel.
- The SD500-ANM can be used to provide one reverse polarity supervised notification appliance circuit.
- The notification circuit can be configured in either Class A (Style Z) or Class B (Style Y).
- The SD500-ANM can be powered by the IntelliKnight Fire Control Panel or by an external 24 VDC source.
Troubleshooting
- If the SD500-ANM is not operating properly, check the following:
- Is the SD500-ANM properly connected to the IntelliKnight Fire Control Panel or external power source?
- Is the notification circuit properly wired?
- Is the notification appliance properly connected to the SD500-ANM?
- If the SD500-ANM is still not operating properly, contact Silent Knight Technical Support for assistance.
Maintenance
- The SD500-ANM requires no routine maintenance.
- However, the notification appliance connected to the SD500-ANM should be inspected and cleaned regularly.
- If the notification appliance is damaged, it should be replaced.
Warranty
- The SD500-ANM is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase.
- If the SD500-ANM becomes defective during the warranty period, it will be repaired or replaced at no charge.
- To obtain warranty service, contact Silent Knight Technical Support.
Contact Information
- Silent Knight
- 100 Corporate Drive
- Temecula, CA 92590
- Phone: (800) 544-2911
- Email: [email protected]
- Website: https://www.silentknight.com/
Additional Information
- The SD500-ANM can be programmed using the IntelliKnight Fire Control Panel programming software.
- For more information on the SD500-ANM, please refer to the IntelliKnight Fire Control Panel Installation Manual.
I hope this manual has been helpful. If you have any questions, please do not hesitate to contact Silent Knight Technical Support.
Comments
Post a Comment